Features | |
|
|
General | |
Style | ALCUL Three-Conductor, Four-Hole Mount |
Material | Aluminum |
Plating | Tin-Plated |
Conductor Range (AL or CU) Maximum | 1000 kcmil |
Conductor Range (AL or CU) Minimum | 500 kcmil |
Dimension Information | |
Length (inches) | 6 3/16 |
Width (inches) | 4 3/4 |
Height (inches) | 1 7/8 |
D (inches) | 5/8 |
E (inches) | 1/2 |
F (inches) | 9/16 |
G (inches) | 3 7/16 |
I (inches) | 1 41/64 |
I am an electrical contractor in Michigan. We do service on cell phone towers in the midwest and areas around the midwest. I am currently looking for an electrical contractor that would be willing to do service calls in the Minnesota area. We pay well. If you are interested please email me at alanogard@msn.com.
kmca255Sai Engineering has been successfully providing power to various industries for the past five decades. Not withstanding our high performance level in the market, we are constantly striving to upgrade our services and technology to meet the stringent demands of. We Provaided by all marine generator.The Company was incepted rightly since 45 years back with the the vision of periodical, sphereodical and radical changes and transformation in development of all the sectors from Industrial, Commercial and Social Aspect. We are into Industrial Generators. We are a leading Suppliers of Diesel Generator Set consisting of Generator Service Provider, Industrial & Residential Diesel Generator, Old Generator for Sale, Used Diesel Generator Sale. From Bhavnagar, Gujarat. Email- info@saidieselgenerator.com www.saidieselgenerator.com mo.9879304079 |
Pay with and your full purchase price is covered
Number of Functions | 8 |
Repeatability Constant Voltage and Temperature | 0.20000000000000001 |
Functions Available | External control of the start - External control for partial stop - On-delay - Off-delay - Interval, start on opening of external control contact - Repeat cycle, with off period start - Repeat cycle, with on period start - Interval |
Reset Time | 50 |
Output Type | Electromechanical |
Contact Configuration | DPDT |
Timing Range | 0.05 s to 300 h |
Minimum Switching Requirement | 12 V per 10 |
Time Scales | 0.05 to 1sec; 0.15 to 3sec; 0.5 to 10sec; 1.5 to 30sec; 5 to 100sec; 15 to 300sec; 1 to 300min; 1.5 to 30min; 1.5 to 30hr; 15 to 300hr |
Contact Materials | AgNi |
Current Rating | 5 |
Degree of Protection | IP50 (Housing) - IP20 (Terminals) |
Input Voltage Range | 24 - 240 VAC/VDC |
Frequency | 50/60 Hz |
Maximum Consumption AC | 2.0 VA (24 VAC) - 2.5 VA (48 VAC) - 3.2 VA (110 VAC) - 6.0 VA (240 VAC) |
Maximum Consumption DC | 1.0 W (48 VDC) - 3.2 W (110 VDC) - 2.0 W (240 VDC) |
Tightening Torque | 4.5 to 9.9 lb-in |
Indication (LED) | 3 |
Mounting Style | Din Rail |
Weight | 149.69999999999999 |
Ambient Air Temperature around the Device - Operation | -20 to 60 |
Approvals | GL - CSA - CE - RoHS - UL |
Ambient Air Temperature around the Device - Storage | -40 to 85 |
Electrical Life (UL508) Operations at Rated Current (Resistive) | 100,000 operations |
Mechanical Life Unpowered | 20,000,000 operations |
Vibration Resistance - Operational | A=0.35 mm |
Shock Resistance | 15 gn - 11 ms |