Register Please register or log in.
may be you forgot your password?

SQUARE D MOTOR CONTROL ...

ONLINE AUCTION. Ends 3.1.17 . To view full details, please go to www.govdeals.com and enter 297-1723 in the QAL (Quick Asset Lookup) search box located on the homepage. AUCTION INCLUDES ALL SQUARE D EQUIPMENT INSIDE BUILDING INCLUDING SQUARE D MOTOR CONTROL CENTER (MCC) MODEL 6 IS 600 AMP RATED AS DESCRIBED BELOW & SHOWN IN PHOTOS:

The main disconnect outside has no cover so most likely not in good condition. • inside fused disconnect is at least a 3 phase 480 volt but probably 600 volt rated (currently has 225 amp fuses installed) • the Sq D transformer is 25KVA rated, cat# 25S3HFCU • the Sq D panel is a NQOD30L225CU with a few breakers installed • Looks like possibly a Sq D lighting contactor above door • the Sq D MCC (Motor Control Center) is 600 amp rated, with 5 sections. Some buckets are labeled spare but the rest used to be active, please see the picture of #2 seepage bucket (opened), it has associated parts still installed. Other buckets are labeled, see below: - Seepage Pump P-1 Control Panel - 120 V Control for RVSS P-1 - Transformer - Surge Suppressor - Seepage Pump No.1 - Remote Control Panel - 120 V Control for RVSS P-2 - Seepage Pump No.2 - Metering - MCB (main circuit breaker)

BUYER MUST REMOVE/DISCONNECT ALL SQUARE D EQUIPMENT INSIDE BUILDING. PROVIDE EQUIPMENT TO LOAD SUCH AS HOIST, GANTRY CRANE, FORKLIFT, ETC. UNPAVED ACCESS ROAD. PICK UP ONLY MONDAY THRU THURSDAY BETWEEN 8:00AM & 4:00PM.

LIABILITY RELEASE MUST BE SIGNED AND PROOF OF INSURANCE IS REQUIRED: $300,000 GENERAL LIABILITY, $300,000 AUTO AND WORKERS COMP. MUST NAME THE S FL WATER MANAGEMENT DISTRICT AS ADDITIONAL INSURED. SEE G350A Equipment Removal Requirements Draft.docx ATTACHMENT FOR FURTHER DETAILS.

LOCATED REMOTE SITE G350A IN HENDRY COUNTY (DOWN A SHORT WAY FROM G508 WHICH IS ADDRESS LISTED WITH THIS POSTING). SEE PHOTO OF ACTUAL BUILDING ITEMS LOCATED IN. NO FACILITIES. BEWARE OF POTENTIAL WASPS.

PROPERTY MAY BE INSPECTED ON WEDNESDAY, FEBRUARY 1ST AT 9:00 AM. BY SCHEDULED APPOINTMENT ONLY! Please contact: Karen Kempf, Phone: (561) 682-2113 or e-mail: kkempf@sfwmd.gov

CONDITION: EQUIPMENT HAS NOT BEEN TESTED AND MOST ITEMS FOR SALE ARE USED AND MAY CONTAIN DEFECTS NOT IMMEDIATELY DETECTABLE. ALL EQUIPMENT ARE SOLD IN "AS-IS" CONDITION. WE STRONGLY RECOMMEND YOU INSPECT EQUIPMENT BEFORE BIDDING!

Allen-Bradley PowerFlex ...

 Allen-Bradley PowerFlex 7000 Air-Cooled Drive Unit & Components - 

 

Allen-Bradley PowerFlex 7000 Power Supply Components: Air-Cooled Drive Unit & Components contained in 10 cabinets on pallets weighing approximately 35,000 lbs. total weight
New components that have never been used and are in excellent condition.
Description Details:
Capabilities Across a Broad Range of Applications
The PowerFlex 7000 drive is a flexible, easy-to-use solution designed to meet diverse application requirements across a wide spectrum of heavy industrial settings.
Controls speed, torque and direction of induction or synchronous AC motors, normal duty or heavy duty.
Broad power range: 150 kW to 25,400 kW (200 Hp to 34,000 Hp)
Achieves near unity power factor throughout the typical operating speed range for variable torque loads
Virtually perfect sinusoidal current and voltage waveforms allow use of standard motors
Accommodates motor cable lengths up to 15 km
EtherNet/IP™ communication interface. Optional interfaces for a variety of network protocols
Drive control: Sensorless vector control or full vector control with tachometer feedback (optional)
Flexible input configurations: Direct-to-Drive (transformerless), Active Front End (AFE) rectifier or 18-pulse rectifier
Patented PowerCage™ allows SGCT replacement in less than ten minutes
Achieve requirements for Safety Integrity Level 3 (SIL 3) and Performance Level e (PL e) with TÜV Certified Safe Torque Off Premier Integration into the Logix control platform with Studio 5000 Logix Designer™ software reduces development and integration time Robust Design -- PowerFlex 7000 higher power drive structures are designed to help contain and redirect energy in the event of an incident with enhanced enclosures and fault containment. Help reduce downtime with built-in diagnostic and detection features that monitor the health of drive components. Synchronous bypass and transfer to control multiple motor systems • Local and remotely mounted HMI options.Remote Virtual Support Engineer™ service available
CATALOG NUMBERS OF MAJOR COMPONENTS:
1.  Two-High, Full Voltage Non-Reversing Starters:
1512B-AAE-1ESTP-1STR-1STP-3L-5OFFG-5RUNR-6-6T-84D284HX-88GA-750RL-802-4010-5025D-CMOD[7,10,13]
2.  Two-High, Full-Voltage transformer Feeder Unit:
1512BT-AAE-1ON-1OFF-5OFFG-50NR-6-7F-89CF40-750RL-802-3950S-4010-CMOD[10]
3.  Empty/Auxiliary Unit:
1599-AAE
4.  Two-High, Full-Voltage Non-Reversing Starter:
1512B-AAE-1ESTP-1STR-1STP-3L-5OFFG-5RUNR-6-6T-84D2-84HX-88GA-750RL-802-4010-5025D-CMOD7
5.  Miscellaneous/Empty Unit:
1599-CAE-CMOD9
1-High VFD Input Contactor units:
1512AD-CAE-5OFFG-50NR-6B-6T-14LRD--84D2-84HX-88GA-750RL-4010-5051-CMOD[7]
6.  Medium Voltage, Air Cooled, Variable Frequency AC Drive Unit:
7000-E430DEBD-RPDTD-1EDSTP-1STR-1STR-1STP-3LL-4DRNR-4DRYG-4FLTR-4WRNA-13COMME-14PVKLC-14TS1-14TS3-14TS4-14TS5-17-8

Please call us with any questions or if you have an interest and would like additional photos of the equipment .                                                                                                                                                   ALL OFFERS WILL BE CONSIDERED        Office:1-888-322-9609 Cell:1-208-651-3736

Schneider Electric Timer ...

 

 

Schneider Electric RE7MY13MW Timer

TIMER 300V 5AMP RE7 +OPTIONS
New Surplus item removed from new equipment not used. Product data sheet imcluded, no box. Shipping anywere in North America $8.00

 Pay with PayPal and your full purchase price is covered

 artur_p@hotmail.com

 

Features and Specifications
Number of Functions 8
Repeatability Constant Voltage and Temperature 0.20000000000000001
Functions Available External control of the start - External control for partial stop - On-delay - Off-delay - Interval, start on opening of external control contact - Repeat cycle, with off period start - Repeat cycle, with on period start - Interval
Reset Time 50
Output Type Electromechanical
Contact Configuration DPDT
Timing Range 0.05 s to 300 h
Minimum Switching Requirement 12 V per 10
Time Scales 0.05 to 1sec; 0.15 to 3sec; 0.5 to 10sec; 1.5 to 30sec; 5 to 100sec; 15 to 300sec; 1 to 300min; 1.5 to 30min; 1.5 to 30hr; 15 to 300hr
Contact Materials AgNi
Current Rating 5
Degree of Protection IP50 (Housing) - IP20 (Terminals)
Input Voltage Range 24 - 240 VAC/VDC
Frequency 50/60 Hz
Maximum Consumption AC 2.0 VA (24 VAC) - 2.5 VA (48 VAC) - 3.2 VA (110 VAC) - 6.0 VA (240 VAC)
Maximum Consumption DC 1.0 W (48 VDC) - 3.2 W (110 VDC) - 2.0 W (240 VDC)
Tightening Torque 4.5 to 9.9 lb-in
Indication (LED) 3
Mounting Style Din Rail
Weight 149.69999999999999
Ambient Air Temperature around the Device - Operation -20 to 60
Approvals GL - CSA - CE - RoHS - UL
Ambient Air Temperature around the Device - Storage -40 to 85
Electrical Life (UL508) Operations at Rated Current (Resistive) 100,000 operations
Mechanical Life Unpowered 20,000,000 operations
Vibration Resistance - Operational A=0.35 mm
Shock Resistance 15 gn - 11 ms



 

Click >>> Subscribe to Our Store Newsletter <<<